Omron NE-C801 User Manual

Browse online or download User Manual for Air compressors Omron NE-C801. Omron NE-C801 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Compressor Nebuliser
Model NE-C801
• Instruction Manual
• Mode d’emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
TMTM
EN
FR
DE
IT
ES
IM-NE-C801S-E-03-11/2011
9487399-6C
NL
AR
RU
NE-C801S-E_B_M02_100827.pdf
NE-C801S-E_M_main.book Page 1 Wednesday, January 11, 2012 12:35 PM
Page view 0
1 2 ... 30

Summary of Contents

Page 1 - NE-C801

Compressor NebuliserModel NE-C801• Instruction Manual• Mode d’emploi• Gebrauchsanweisung• Manuale di istruzioni• Manual de instrucciones• Gebruiksaan

Page 2 - Contents

103. Preparing the nebuliser for useWarning:Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first t

Page 3 - Intended use

113. Preparing the nebuliser for useEN3.2 Adding medication and assembling the parts1. Remove the mouthpiece and cap from the nebuliser kit.2. Remove

Page 4 - Important safety instructions

123. Preparing the nebuliser for use6. Attach the desired inhalation attachment, as described below.Attaching the mouthpiece1) Attach the cap to the i

Page 5

133. Preparing the nebuliser for useEN7. Attach the air tube.1) Twist the air tube plug slightly and push it firmly into the air tube connector on the

Page 6

144. Taking medication1. Hold the nebuliser kit as indicated on the right.Caution: Do not tilt the nebuliser kit at an angle of greater than 45° in al

Page 7 - 1. Know your unit

154. Taking medicationEN3. Inhale medication according to your doctor’s and/or health care adviser’s instructions.Prepare the inhalation attachment ac

Page 8 - 9487399-6C

164. Taking medication4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug th

Page 9 - 2. Guide to using the device

17EN5. Cleaning and daily disinfecting5.1 CleaningFollowing the cleaning instructions after each use will prevent any remaining medication in the tank

Page 10 - 3.1 Connecting AC adapter

185. Cleaning and daily disinfecting7. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent.Caution: The

Page 11

195. Cleaning and daily disinfectingENHandling the Vaporiser HeadThe vaporiser head is an important part that is used to vaporise medication.Be sure t

Page 12

2ContentsBefore using the deviceIntroduction ... 3Inte

Page 13 - 7. Attach the air tube

205. Cleaning and daily disinfectingUse the table below as a guideline to select a method for disinfecting.Parts Model MaterialsMouthpiece C28-3P-E PP

Page 14 - 4. Taking medication

215. Cleaning and daily disinfectingENO: applicable ×: not applicable* an example of commercially available disinfectant.BoilingAlcoholSodium hypochlo

Page 15

226. Maintenance and storageTo keep your device in the best condition and protect the device from damage follow these directions:Caution:• Do not leav

Page 16

23EN7. Changing the air filterIf the air filter has changed colour, or has been used on average for more than 60 days, replace it with a new one.1. Pu

Page 17

248. TroubleshootingCheck the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instruc

Page 18

25EN9. Technical data Notes:• Subject to technical modification without prior notice.• This OMRON product is produced under the strict quality system

Page 19 - Handling the Vaporiser Head

269. Technical dataTechnical data for the OMRON NE-C801 Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit:Result of cascade im

Page 20

279. Technical dataENImportant information regarding Electro Magnetic Compatibility (EMC)With the increased number of electronic devices such as PC’s

Page 21

289. Technical dataCorrect Disposal of This Product(Waste Electrical & Electronic Equipment)This marking shown on the product or its literature, i

Page 22 - 6. Maintenance and storage

29EN10.Optional parts and accessoriesOmron V.V.T. Nebuliser Kit N-01 SetModel: C801S-NSET3-EOrder No.: 9515573-6Air Tube (PVC, 100cm)Model: C801S-ATBP

Page 23 - 1. Pull the air filter cover

3ENIntroductionThank you for purchasing the OMRON COMP AIR.This product was developed in conjunction with respiratory therapists for the successful tr

Page 24 - 8. Troubleshooting

3010. Optional parts and accessoriesMade in ChinaManufacturer OMRON HEALTHCARE Co., Ltd.53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPANEU-repre

Page 25 - 9. Technical data

4Important safety instructionsRead all the information in the instruction manual and any other literature included in the box before using the device.

Page 26 - Cumulative Undersize %

5 Important safety instructionsEN• Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device.• Do not operate the device

Page 27

6 Important safety instructions• Do not block the slit between the cap and the inhalation air inlet.• Do not use a microwave oven or hair dryer to dry

Page 28

7EN1. Know your unitAir Tube (PVC, 100cm)Air Tube ConnectorNebuliser Kit HolderAir Filter Cover*Air filter insidePower ConnectorCompressor (Main Unit)

Page 29 - Mouthpiece

81. Know your unitAccessories Compressor NebuliserModel NE-C801• Instruction Manual• Mode d’emploi• Gebrauchsanweisung• Manuale di istruzioni• Manual

Page 30 - Made in China

9EN2. Guide to using the devicePreparing the Nebuliser for Use - Section 3 (page 10-13)Warning:Clean and disinfect the nebuliser kit, mouthpiece and n