Section 3 SETUP
Section 3
Setting I/O Assignments
3-17
ZS-MDC
User’s Manual
Changing Output Assignments
FUN mode-[I/O SET]-[I/O SET]-[OUT]
Changing Linear Output Assignments
FUN Mode-[I/O SET]-[I/O SET]-[ANALOG]
About Digital Output
FUN Mode-[I/O SET]-[I/O SET]-[DIGITAL]-[LOG1 to 9]
Setting Description
TASK1
TASK2
TASK3
TASK4
The measurement value of the task selected here is output as the judgment result
of the Multi-Controller.
Setting Description
TASK1
TASK2
TASK3
TASK4
The measurement value of the task selected here is linear-output from the Multi-
Controller.
Setting Description
NONE
Input A to input I
TASK1 to TASK4
Set this to batch-output multiple data to external devices using CompoWay/F or
non-procedural commands.
Assign to log 1 to 9 inputs A to I or TASK1 to 4 to be output. When a command is
input, the inputs or tasks are output continuously in order from log 1 to 9.
(The data of the nine channels can be batch-output when input A to I is set to log1
to 9 with all inputs assigned.)
For details on commands, refer to the “Communication Command Reference”
(provided separately).
When multi-channel waveforms are plotted or logging is performed on SmartMon-
itor Zero, the details set on SmartMonitor Zero are automatically reflected in this
setting.
▲▲
Page view 54