4-12
Section 4 APPLICATION SETTING EXAMPLES
ZS-MDC
User’s Manual
Section 4
Measuring the Average Height
Measuring the Average Height
This is an example of how to measure the height at 3 locations on a workpiece, and
calculate the average of each measured height value. [AVERAGE] is used as the
operation mode.
For details on how to connect and install the Sensor Heads and Sensor Controllers, refer to the “ZS-L
User’s Manual”.
FUN Mode-[SENSING]-[SEL CH]
1. Assign the CH No. of the controller to inputs
A to C to be used for the expression.
INPUT A:1CH
INPUT B:2CH
INPUT C:3CH
Press MENU key - ESC key.
2. Select [TASK1].
Input A Input B Input C
Input A Input B Input C
CH0 CH1 CH2 CH3
The operation and/or measurement results are output
as judgement output or linear output.
1INPUT A
3INPUT C
2INPUT B
1TASK1
3TASK3
2TASK2
4TASK4