Section 4 APPLICATION SETTING EXAMPLES
Section 4
Measuring the Twist of a Workpiece
4-15
ZS-MDC
User’s Manual
Press MENU key - ESC key.
2. Select [TASK1].
[SENSING]-[CALC]-[CALC]-[STEP]
3. Set the expression of TASK1.
INPUT X: INPUT A
INPUT Y: INPUT B
4. Following the same procedure as 2 to 3, set
up TASK2.
INPUT X: INPUT D
INPUT Y: INPUT C
5. Following the same procedure as 2 to 3, set
up TASK2.
INPUT X: TASK 1
INPUT Y: TASK 2
1TASK1
3TASK3
2TASK2
4TASK4
1INPUT X 2 INPUT Y
Input A
Input B
Input C
Input D
Input A
Input B
Input C
Input D
Input A
Input B
Input C
Input D